Showing 7–12 of 25 results
GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.
The High voltage tester for routine testing of MCBs combines a conventional high voltage tester with a specially designed robust fixture to hold 20 single pole MCBs at a time. The solution comes as a single trolley with easy-to-set test parameters with safety interlocks designed for user safety with respect to electric shock and mechanical fixturing. An advantage of the system is – it gives a high yield (20 MCBs are tested in about one minute) thus yielding user safety at a high value for money.
SCR ELEKTRONIKS Impulse Voltage Testers and Surge Current Testers are designed for interference test as per IEC 61180. Impulse Voltage Testers produce a Voltage Impulse of the required 1.2 / 50 microsecond waveform, meaning a high voltage pulse with 1.2 microseconds rise time and 50 microseconds fall time. The voltage level is settable from 0.5kV to 25kV (depending upon model). Likewise, the Surge Testers will produce a current surge with the required wave-shape of 8 / 20 microsecond, meaning a high current surge with 8 microseconds rise time and 20 microseconds fall time.
The SCR Elektroniks Endurance Test Bench is designed for electrical and mechanical endurance MCB and RCCB as per clause 9.11 of IEC 60898-1. The source and the load is designed to comply as per the general test conditions specified in Cl 9.11.1. The accompanying pneumatic fixture is designed to hold custom built designs of MCB and RCCB while the microcontroller based timer unit can be configure to follow test procedure summarized in Cl 9.11.2.
The SCR Elektroniks MCB Instantaneous Trip Test Bench is designed for Testing of MCB to carry out “Test of Instantaneous Tripping and of correct opening of the Contacts” as per IEC: 60898-1:2002 Clause 9.10.2 at rated voltage. This test is carried out with power factor between 0.95 and 1 with the sequence operation being O-t-CO-t-CO-t-CO with timings as specified in 9.12.11.1.
The SCR Elektroniks 3 station MCB Temperature Rise and Power Loss Test Bench is economically designed to verify temperature rise and measure power loss as per clause 9.8 of IEC 60898 with the circuit designed to follow test procedure as per Cl 9.8.2. The temperature rise is measured in accordance with Cl 9.8.3 and 9.8.4 while power loss is measured and verified as per Table 15 of Cl 9.8.5.
