GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.
Glow wire apparatus is the commonly used equipment for testing solid insulating material for fire hazard testing. This test apparatus is covered in IEC 60695-2-10:2021 and commonly referred for various devices in many standards such as IEC 60335, IEC 60695-2-11, IEC 60695-2-12, IEC 60598-1, IEC 60947, IEC 60898, IEC 61008-1, IEC 60669-1, IEC 60884-1, IEC 60950-1 / IS 13252, IEC 60238, IEC 60745-1, IEC 60400, IEC 60730-1, IEC 61050, IEC 60320-1, IEC 61058-1, ASTM D 6194-03 and UL 60745-1.
GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.
An air-pressurized launcher discharges ice balls resembling hailstones of a predetermined size at the module or collection positioned on the support frame of the hail impact test stand. The hail impact test is an important solar panel quality and safety test since hail can cause severe damage to solar panels in many places of the world. As a result, it’s critical to install solar that has been tested for hail impact and has passed the hail impact test for solar panels.
The High voltage tester for routine testing of Switches & Sockets with a specially designed robust fixture to hold ither 20 Nos. switches one way or two way 20 Nos. and 10 Nos. Sockets at a time. The solution comes as a single trolley with easy-to-set test parameters with safety interlocks designed for user safety with respect to electric shock and mechanical fixturing. An advantage of the system is – it gives a high yield (20 Switches OR Sockets are tested in about one minute) thus yielding user safety at a high value for money
The High voltage tester for routine testing of MCBs combines a conventional high voltage tester with a specially designed robust fixture to hold 20 single pole MCBs at a time. The solution comes as a single trolley with easy-to-set test parameters with safety interlocks designed for user safety with respect to electric shock and mechanical fixturing. An advantage of the system is – it gives a high yield (20 MCBs are tested in about one minute) thus yielding user safety at a high value for money.